亚洲精品自拍_男生c女生_天天操天天舔_av在线免费观看网站_萌白酱在线观看_成人免费在线电影_韩日av在线_可以看毛片的网站_久久久久久久久久国产_国产精品999999_91蓝莓视频_成人免费视频播放_曰韩三级_黑人精品一区二区三区_亚洲老老头同性老头交j_成人福利网址_亚洲制服av_欧美日韩亚洲系列

E510 series inverter

TECO Inverter E510 is a multi-functional vector inverter equipped with a 32-bit RISC processor and built-in PLC. It integrates safe stop (STO) and fire mode (Fire Mode). It can automatically adjust the carrier wave according to the operating temperature to reduce heat accumulation in the inverter. , the fan automatically detects temperature and starts, supports multiple communication protocols and copy modules, the operator can be pulled out, and complies with CE and UL safety certifications.

  • Brand: TECO
  • Type: E510

Multifunctional vector inverter, equipped with 32Bit RISC processor, built-in PLC, integrated safe stop (STO) and fire mode (Fire Mode), can automatically reduce the carrier according to the operating temperature, reduce heat accumulation in the inverter, and the fan automatically detects temperature Start, supports multiple communication protocols and copy modules, and the operator can be pulled out to comply with CE and UL safety certifications.


Features of TECO inverter E510: multifunctional universal inverter

TECO inverter E510 rated voltage and power range:

220V model

  • Power range: 0.4~15KW single/three-phase shared

  • Input voltage: 200V~240V

380V model

  • Power range: 0.75~18.5KW single

  • Input voltage: 380V~480V

  • Protection level: IP20

  • International certification: UL, CE

Features of TECO inverter E510:

  • Control method: vector control, v/f control

  • All series have built-in PLC for program control

  • All series have built-in rs-485 communication port (rj45)

  • The entire series has input and output phase loss protection functions

  • All series have input terminal counting function

  • Two analog inputs can be superimposed or acted independently

  • Unique low current detection function

  • Unique analog input monitoring function

  • Unique input and output terminal status display function makes control more convenient and faster

  • Unique fire mode settings

  • Parameters such as voltage, current, and frequency during alarm can be viewed to facilitate troubleshooting.


ModelVoltage
E510-2P5-H200-240V single three-phase
E510-2P5-H
E510-2P5-H1F200-240V single phase
E510-2P5-H1F
E510-401-H380-480V three phase
E510-402-H
E510-401-H1F
E510-402-H1F
E510-202-H200-240V single three-phase
E510-203-H
E510-202-H1F200-240V single phase
E510-203-H1F
E510-205-H3200-240V three phase
E510-403-H3380-480V three phase
E510-405-H3
E510-403-H3F
E510-405-H5F
E510-208-H3200-240V three phase
E510-210-H3
E510-408-H3/H3F380-480V three phase
E510-410-H3/H3F
E510-415-H3/H3F
E510-215-H3200-240V three phase
E510-220-H3
E510-420-H3/H3F380-480V three phase
E510-425-H3/H3F



Phone Number
Inquiry Form
E-Mail